UDK Comparison
| A | B | C | D | E | F | |
|---|---|---|---|---|---|---|
| UDK10X | UDK20X | UDK25X | UDK31X | UDK35X | ||
| 1 | fallen bottle detection |
opt | opt | opt | opt | opt |
| 2 | blocked bore detection |
opt | opt | opt | opt | opt |
| 3 | scrap detection |
opt | opt | opt | opt | opt |
| 4 | UL/CSA approval |
v | v | v | v | v |
| 5 | test on running conveyor |
v | v | v | v | v |
| 6 | positive testing(push over good bottles) |
v | v | v | v | – |
| 7 | angled neck |
v | v | v | v | v |
| 8 | test leak |
v | v | v | v | v |
| 9 | Recipes | v | v | v | v | v |
| 10 | Text interface |
v | v | – | – | – |
| 11 | AD converter divisions |
1024 | 1024 | 8000 | 8000 | 32768 |
| 12 | AD speed (samples /sec) |
1000 | 1000 | 2000 | 2000 | 2000 |
| 13 | filtering (moving average) |
none | none | 64 samples | 64 samples | 10 samples |
| 14 | Grapical user interface |
– | – | v | v | v |
| 15 | touch screen |
– | – | v | v | v |
| 16 | speed adaptation trough screen |
– | v | v | v | v |
| 17 | interface at eye height |
– | v | v | v | v |
| 18 | basic error counter (good/bad, max 9999) |
v | v | – | – | – |
| 19 | error counters per error type/per head, max 99999999 |
– | – | v | v | v |
| 20 | graph trending |
– | – | v | v | – |
| 21 | every bottle logging |
– | – | v | v | v |
| 22 | basic test information |
v | v | v | v | v |
| 23 | extended test information |
– | – | v | v | v |
| 24 | on the fly testing |
– | – | – | – | v |
| 25 | Auto tuning |
– | – | v | v | v |
| 26 | connectivity through networks (E-Net/Profibus/Devicenet) |
– | – | opt | opt | opt |
| 27 | adaptive flyback |
– | – | – | – | v |
| 28 | max no of heads |
1 | 1 | 1 | 4 | 4 |
| 29 | error history |
– | – | v | v | v |
| 30 | typical speed for 1L bottles (0.22 leak) |
1500-1800 | 1500-1800 | 1700-2000 | 1700-5000 | 8000-18000 |