UDK Comparison
A | B | C | D | E | F | |
---|---|---|---|---|---|---|
UDK10X | UDK20X | UDK25X | UDK31X | UDK35X | ||
1 | fallen bottle detection |
opt | opt | opt | opt | opt |
2 | blocked bore detection |
opt | opt | opt | opt | opt |
3 | scrap detection |
opt | opt | opt | opt | opt |
4 | UL/CSA approval |
v | v | v | v | v |
5 | test on running conveyor |
v | v | v | v | v |
6 | positive testing(push over good bottles) |
v | v | v | v | – |
7 | angled neck |
v | v | v | v | v |
8 | test leak |
v | v | v | v | v |
9 | Recipes | v | v | v | v | v |
10 | Text interface |
v | v | – | – | – |
11 | AD converter divisions |
1024 | 1024 | 8000 | 8000 | 32768 |
12 | AD speed (samples /sec) |
1000 | 1000 | 2000 | 2000 | 2000 |
13 | filtering (moving average) |
none | none | 64 samples | 64 samples | 10 samples |
14 | Grapical user interface |
– | – | v | v | v |
15 | touch screen |
– | – | v | v | v |
16 | speed adaptation trough screen |
– | v | v | v | v |
17 | interface at eye height |
– | v | v | v | v |
18 | basic error counter (good/bad, max 9999) |
v | v | – | – | – |
19 | error counters per error type/per head, max 99999999 |
– | – | v | v | v |
20 | graph trending |
– | – | v | v | – |
21 | every bottle logging |
– | – | v | v | v |
22 | basic test information |
v | v | v | v | v |
23 | extended test information |
– | – | v | v | v |
24 | on the fly testing |
– | – | – | – | v |
25 | Auto tuning |
– | – | v | v | v |
26 | connectivity through networks (E-Net/Profibus/Devicenet) |
– | – | opt | opt | opt |
27 | adaptive flyback |
– | – | – | – | v |
28 | max no of heads |
1 | 1 | 1 | 4 | 4 |
29 | error history |
– | – | v | v | v |
30 | typical speed for 1L bottles (0.22 leak) |
1500-1800 | 1500-1800 | 1700-2000 | 1700-5000 | 8000-18000 |